Document Details

Document Type : Article In Journal 
Document Title :
FRACTURE STRENGTH AND MICROLEAKAGE OF LAMINATE VENEERS
FRACTURE STRENGTH AND MICROLEAKAGE OF LAMINATE VENEERS
 
Document Language : English 
Abstract : The present investigation was doneto measure fracture strength and microleakag of laminate veneers. Thirty maxillary anterior teeth were selected and .divided into three equal groups ( 10 teeth for each design ). Design {A}; teeth were prepared with feather edge. Design {B}; teeth prepared with) 2 mm incisal reduction without palatal chamfer and, Design {C} 2mm incisal reduction with lmm palata chamfer .In-ceram laminate veneers were constructed with three different preparation design and cemented on its corresponding prepared teeth with resin cement,then the tested specimens were thermocylced for 48 hours then the frilcture strength was . measured using L loyed testing machine at cross-head speed of 0.5 mm/min. The microleakage were measured usinf stereomicroscope for fifteen specimens.The result were statistically analysed ysing ANOVA and "t" test.It was concluded that highest fracture strength was found design {B{ and microleakage was found to be higher in cervical margin than incisal in the three different designs and highest in palatal margin of esign {C} than design {A} and Design{B}The present investigation was doneto measure fracture strength and microleakag of laminate veneers. Thirty maxillary anterior teeth were selected and .divided into three equal groups ( 10 teeth for each design ). Design {A}; teeth were prepared with feather edge. Design {B}; teeth prepared with) 2 mm incisal reduction without palatal chamfer and, Design {C} 2mm incisal reduction with lmm palata chamfer .In-ceram laminate veneers were constructed with three different preparation design and cemented on its corresponding prepared teeth with resin cement,then the tested specimens were thermocylced for 48 hours then the frilcture strength was . measured using L loyed testing machine at cross-head speed of 0.5 mm/min. The microleakage were measured usinf stereomicroscope for fifteen specimens.The result were statistically analysed ysing ANOVA and "t" test.It was concluded that highest fracture strength was found design {B{ and microleakage was found to be higher in cervical margin than incisal in the three different designs and highest in palatal margin of esign {C} than design {A} and Design{B} 
ISSN : 11106786 
Journal Name : Cairo Dental Journal 
Volume : 25 
Issue Number : 2 
Publishing Year : 1430 AH
2009 AD
 
Article Type : Article 
Added Date : Sunday, June 27, 2010 

Researchers

Researcher Name (Arabic)Researcher Name (English)Researcher TypeDr GradeEmail
عبد الغني ميرهMirra, Abd-EI Ghani InvestigatorDoctorate 

Files

File NameTypeDescription
 27139.pdf pdf 
 27140.pdf pdf 

Back To Researches Page