Document Details

Document Type : Article In Journal 
Document Title :
FLEXIBILITY AND MICROSTRUCTURE OF ROUND AND HALF-ROUND CIRCUMFERENTIAL CLASPS IN COMPARISON WITH WROUGHT WIRE CLASP
FLEXIBILITY AND MICROSTRUCTURE OF ROUND AND HALF-ROUND CIRCUMFERENTIAL CLASPS IN COMPARISON WITH WROUGHT WIRE CLASP
 
Document Language : English 
Abstract : The objective of this study was to compare the flexibility and microstructure of 20 gauge round and half-round cast Ticonium clasps with that of the same gauge Ticonium wrought wire clasp. Cast and wrought wire test specimens were processed and prepared for flexibility testing which accomplished by a universal testing machine for recording the load displacement curves. Then, they were mounted, polished and etched for microstructure testing using the metallurgical microscope. The results indicated that wrought wire clasps showed the highest recorded flexibility value, followed by round and then half-round cast clasps. Microstructure photographs revealed a mild difference in granular structure between wrought and both cast clasps as regard grain size, shape and distribution which had been reflected obviously upon flexibility test results. Keywords: Flexibility, Microstructure, Removable partial denture, Round clasp, Half-round clasp, Wrought wire clasp. 
ISSN : 1687-1693 
Journal Name : Tanta Dental Journal 
Volume : 8 
Issue Number : 1 
Publishing Year : 1432 AH
2011 AD
 
Article Type : Article 
Added Date : Sunday, April 15, 2012 

Researchers

Researcher Name (Arabic)Researcher Name (English)Researcher TypeDr GradeEmail
مجدي مصتفيMostafa, Magdy Investigator  

Files

File NameTypeDescription
 32829.pdf pdf 

Back To Researches Page